TSM9 Kalıplı Kasa Devre Kesici

Temel Bilgiler
  1. Örnek TSM9-100L;TSM9-400L

Ürün Açıklaması

Başvuru

TSM9 moulded case circuit breaker supplied with rated insulation voltage 1000V is used for circuit of AC 50/60Hz, rated operating voltage AC 690V and rated operating current up to 1600A for infrequent changing over and starting of the motors.
Equipped with the protection devices against over current, short circuit and under voltage, the product is capable of preventing damage of circuits and supply units. The product can be used to replace a load switch with isolation function. The products comply with IEC60947-2.
The product is equipped with an intelligent controller with LCD display. Rated operating current, overload setting current, short circuit delay current, short circuit instantaneous current, tripping time, as well as short circuit instantaneous three-stage protection and under voltage protection can be set in advance.
The product is also equipped with RS485 communication interface and MODBUS-RTU protocol, DL/T 645 protocol.
The following indication can be chosen by the users:
Remote signal: breaking closing, tripping, alarm and fault status indication;
Remote control: breaking, closing, resetting;
Telemetry: three phase current and N phase current, grounding current, trip memory
function, and functions such as querying trip recording parameters.

Şartname

Örnek TSM9-100 TSM9-160 TSM9-250 TSM9-400 TSM9-630 TSM9- 1600
Kutup Sayısı 3P, 4P
Shell Frame Maximum Rated Current Inm(A) 100 160 250 400 630 1600
Rated Current ln(A) 12.5,16,20,
25,32,40,
50,63,80,
100
16,20,25,
32,40,50,
63,80,100,
125,160
100,160,
180,200,
225,250
250,315,
350,400
400,500,
630
630,800,
1000,1250,
1600
Rated Insulation Voltage Ui 1000V
Rated Impulse Withstand Voltage Uimp 8000V
Rated Voltage Ue AC 400V/415V 50/60HZ
Flying arc Distance (mm) 0
Rated Ultimate Short Circuit Breaking Capacity Icu(kA) 400/415V L=50kA, M=85kA, H=100kA L=50kA
Rated Service Short Circuit Breaking Capacity lcs(kA) 400/415V Ics=100%Icu
Kullanım Kategorisi A A A B B B
Rated Short Time Withstand Current lcw (kA)(1s) / 5.0kA/1s
Elektriksel Ömür (kez) 10000 8000 8000 6000 5000 1500
Mekanik Ömür (kez) 20000 20000 20000 10000 10000 10000

Micrologic 5.0E measurement function

Koruma
İşlev
Akım (A) Aşırı yük koruması
Short circuit short delay protection
Instantaneous action protection
(4P) Netural line protection
Grounding protection
Current unbalance protection
Overload preliminary warning
Voltage (V) Breaking zero
Voltage unbalance protection
Over frequency and under frequency protection
Phase sequence protection
Measurement
İşlev
Akım (A) Phase current and neutral line current
Average phase current
The maximum value of phase current and neutral line current
Percentage of ground faults
Interphase unbalanced current value
Voltage (V) Line voltage
Phase voltage
Average line voltage
Average phase voltage
Unbalanced line voltage, unbalanced phase voltage
Phase sequence
Frequency (Hz)
Güç Aktif
Reactive
Apparent
Güç faktörü
Electricity Active (kWh), Reactive (kVARh), Visual (kVAh)
Bakım
İşlev
The figures record Times of all kinds of prection of tripping
MAX/MIN value record Max/Min record of current and voltage from each phase
Record Trip ,alarm and deflection record
Contact wear Contact abrasive wear record
Times of operation The times of operation record
RTC Function Realtime clock
Auxiliary alarm detection function function Auxiliary alarm detection, display the state of circuit breaker
Electric operation control function Remote electric operation control function
Human and machine interaction LED display
LCD display
Enter setting
Communication function Modbus RTU DL/T645