Application
BFD1 BFD2 BFD3 series fuse switch disconnector is integrated with initiating current transformer and fuse switch in circuit with rated working current of 160A, 250A, 400A, 630A or 800A 50/60Hz. These fuse switch disconnectors provide reliable overload and short circuit protection for distribution facility, such as cable branch box, box transformer in industrial plants, cormnunity and other infrastructure as well.
Specification
Model | BFD1-1 60 | BFD1-250 | BFD1-400 | BFD1-630 |
Rated Operational Voltage (Ue) | 690V | |||
Rated Operational Current (le) | 160A | 250A | 400A | 630A |
Fuse Size | 00 | 1 | 2 | 3 |
Rated Insulation Voltage (Ui) | 1000V | |||
Rated Impulse Withstand Voltage (Uimp) | 12KV | |||
Degree of Protection | IP10 | |||
Mechanica Life (times) | 2000 | |||
Wire Specifications | 10-95mm2 | 120mm2 | 240mm2 | 300mm2 |
Method Connecting Wire | Screw & V-Clamp | |||
Installation Method | Screw & Hook | |||
Use Classes | AC-21B AC-22B AC-23B | |||
Standard | IEC/EN60947-3 | |||
Rated Short Circuit Current (q) | 120KA | |||
Rated Short Time Current (Icw) | 16KA/1s | |||
Screw Fastening | M8/M10/M12 | |||
Ambinet Temperature | -45°C~+50°C |
Model | BFD2-160 | BFD2-250 | BFD2-400 | BFD2-630 | BFD2-800 |
Rated Operational Voltage (Ue) | 690V | ||||
Rated Operational Current (le) | 1 60A | 250A | 400A | 630A | 800A |
Fuse Size | 00 | 1 | 2 | 3 | 3 |
Rated Insulation Voltage (Ui) | 1000V | ||||
Rated Impulse Withstand Voltage (Uimp) | 12KV | ||||
Degree of Protection | IP20 | ||||
Mechanica Life (times) | 2000 | ||||
Wire Specifications | 10-70mm2 | 120mm? | 240mm2 | 300mm2 | 2x240mm2 |
Method Connecting Wire | Screw & V-Clamp | ||||
Installation Method | Screw & Hook | ||||
Use Classes | AC-21B AC-22B AC-23B | ||||
Standard | IEC/EN60947-3 | ||||
Rated Short Circuit Current (q) | 120KA | ||||
Rated Short Time Current (Icw) | 16KA/1s | ||||
Screw Fastening | M8/M 10/M12 | ||||
Ambinet Temperature | -45°C~+50°C |
Model | BFD3-160 | BFD3-250 | BFD3-400 | BFD3-630 | BFD3-800 |
Rated Operational Voltage (Ue) | 690V | ||||
Rated Operational Current (le) | 160A | 250A | 400A | 630A | 800A |
Fuse Size | 00 | 1 | 2 | 3 | 3 |
Rated Insulation Voltage (Ui) | 1000V | ||||
Rated Impulse Withstand Voltage (Uimp) | 12KV | ||||
Degree of Protection | IP20 | ||||
Mechanica Life (times) | 2000 | ||||
Wire Specifications | 10-70mm2 | 120mm2 | 240mm2 | 300mm2 | 2x240mm2 |
Method Connecting Wire | Screw & V-Clamp | ||||
Installation Method | Screw & Hook | ||||
Use Classes | AC-21B AC-22B AC-23B | ||||
Standard | IEC/EN60947-3 | ||||
Rated Short Circuit Current (q) | 120KA | ||||
Rated Short Time Current (Icw) | 16KA/1s | ||||
Screw Fastening | M8/M 10/M12 | ||||
Ambinet Temperature | -45°C~+55°C |
Dimensions
WhatsApp us